QDSJL Pneumatic F.R.L. (Filter & Regulator & Lubricator)




QDSJL Pneumatic F.R.L. (Filter & Regulator & Lubricator)
For Air Operated Diaphragm Pumps, in order to extend the service life of the pump, it is strongly recommended to use the Pneumatic F.R.L.(Air Filter+Pressure Regulator+Oil Lubricator).
The oil in the Oil Lubricator can enter the air valve chamber with high-pressure air to lubricate the parts in the air valve chamber, avoiding damage to these parts due to dry grinding.
Introduction
QDSJL Pneumatic F.R.L.
Pressure Regulator | Adjust the flow rate by adjusting the air source. | 1. When using the pneumatic F.R.L,it must be fixed,not suspended,and the instalation location should be convenient for maintenance. 2. Please add oil(ISOvg32 or the same grade)to the lubricator before use, and the amount of oil should not exceed 80% of the cup. 3. The fiter must be drained frequently, before the water level reaches the level below the filter holder. 4. When the air volume at the outlet is significantly reduced, the filter element should be replaced in time. |
Pressure Gauge | Convenient to observe the air pressure. | |
Air Filter | Filter impurities and moisture in the air source to prevent impurities from entering the air valve chamber and affecting the pump's work. | |
Lubricating Oil Cup | Automatically inject lubricating oil into the air valve chamber to maintain vulnerable parts. |
Pneumatic F.R.L Selection Guide
![]() |
QDSLJ-A Type A: QBY3-10~25 |
![]() |
QDSLJ-C Type C: QBY3-50~100 |
![]() |
QDSLJ-B Type B: QBY3-25~40 |
![]() |
QDSLJ-D Type D: QBY3-125 |
Function 1. Convenient to observe the air inlet pressure and adjust it. 2. Filter moisture and impurities in the air to reduce the freezing of the muffler. 3. Lubricate the components in the air chamber to reduce wear and extend the life of the components. |
Steps for Replacing the Filter Element
1. Pull down the lock buckle, you are rotati-ng to remove the prot-ective shell. | 2. Remove the trans-parent inner cup. |
![]() |
|
4. Install the inner cup and protective cover to complete the repla-cement. | 3. Remove the filter element fixing nut by rotating countercloc-kwise and replace the filter element. |
Specification Parameters
Model | QDSLJ-A | QDSLJ-B | QDSLJ-C | QDSLJ-D |
Applicable Diaphragm Pump Models | QBY3-10~25 | QBY3-25~40 | QBY3-50~100 | QBY3-125 |
Port Size | 1/4'' | 3/8'' | 1/2'' | 3/4'' |
Working Medium | Air | |||
Filter Element Accuracy | 40μ | |||
Set Pressure Range | 0.05-0.85Mpa | |||
Max.Operating Pressure | 0.95Mpa | |||
Proof Pressure | 1.5Mpa | |||
Ambient Temperature |
5-60℃ | |||
Water Filter Cup Capacity |
15CC | |||
Oil Supply Cup Capacity | 25CC | |||
Recommended lubricating oil |
ISO VG32 or equivalent |