BFQJ-25 1'' Air Operated Diaphragm Pump (AOD PUMP) with Diaphragm Rupture Alarm Device

BFQJ-25 1'' Air Operated Diaphragm Pump (AOD PUMP) with Diaphragm Rupture Alarm Device - 1 BFQJ-25 1'' Air Operated Diaphragm Pump (AOD PUMP) with Diaphragm Rupture Alarm Device - 2

BFQJ-25 1'' Air Operated Diaphragm Pump (AOD PUMP) with Diaphragm Rupture Alarm Device

Model: BFQJ-25P
Max.Flow: 116L/min     
Max. Suction Height: 5.48m 
Fluid Inlet/Outlet Size: 1'' BSP  
Max. Particle Size: 3.2mm    
Air Comsumption: 0.67m³/min

Introduction

BFQJ series diaphragm rupture alarm device sends a signal and shuts down the diaphragm pump as soon as the diaphragm ruptures, which can minimize the possibility of material leakage and eliminate the fault in the first time to ensure production.

Working Principle: The diaphragm pump with diaphragm rupture alarm has two groups of diaphragms, namely the first diaphragm and the second diaphragm. The first diaphragm is in direct contact with the material, and a closed cavity is formed between the second diaphragm and the first diaphragm. During operation, when the first diaphragm ruptures, the material will enter the closed cavity 2, and at the same time, the material will pass through the right-angle ferrule pipe joint, stainless steel pipe, and three-way ferrule pipe joint, and finally flow out from the middle outlet of the ferrule three-way pipe joint. After the material enters the material sensing cylinder, the sensor in the sensing cylinder will send a signal, which can be connected to control components such as PLC to realize signal feedback. The user can perform necessary logical operations based on the signal to realize early warning to ensure that the user is aware of the early warning information that the diaphragm pump diaphragm has ruptured at the first time. In addition, the sensor output signal can also realize sound and light alarms, automatically shut down the pump and other functions.

Installation Drawing

BFQJ-25P316LTFF

BFQJ SERIES
The diaphragm rupture alarm device sends a signal and shuts down the diaphragm pump as soon as the diaphragm ruptures, which can minimize the possibility of material leakage and eliminate the fault in the first time to ensure production.

Product Features

There are 2 independent sealed chambers in the alarm device, and the liquid will enter the sealed chamber without leakage after the diaphragm ruptures.
The liquid entering the sealed cavity pushes the float switch up through the connecting pipe, thereby disconnecting the circuit.
When the circuit is disconnected, the copper solenoid valve installed at the airinlet automatically closes and cuts off the power supply, so that the pump stops working.
The output signal can be additionally connected to PLC and other control systems.

 

Specification Parameters

Diaphragm Pump with Diaphragm Rupture Alarm Device
Model  Max. Flow
L/min
Max. Suction Heightm Inlet/outlet
size(in)
Max. Particle Sizemm

Air 

Comsumption (m3/min)

BFQJ-25 116 5.48 1 3.2 0.67
BFQJ-40 378.5 5.48 1-1/2 4.8 0.9
BFQJ-50 568 5.48 2 6.4 1.5~2.0
BFQJ-80 1041 7.6 3 9.4 3
GODO